| Form factor: |
Plug-in unit for Nimbra 600 series switches 1 interface slot |
|
Interface, common: Ports
Return loss |
8 x BNC, 75 Ohm, Configurable 3G/HD/SD-SDI or ASI, In/Out/Monitor >10 dB @ 3G, >15 dB @ HD, >20 dB @ SD
|
|
Interface, 3G-SDI: Standard Frequency |
SMPTE 424M 3 Gbps SDI 2.97 or 2.97/1.001 Gbps
|
|
Interface, HD-SDI: Standard
Frequency |
SMPTE 292M HD-SDI SMPTE 348M HD-SDTI 1.485 or 1.485/1.001 Gbps
|
|
Interface, SD-SDI: Standard
Frequency |
SMPTE 259M SD-SDI SMPTE 305M SD-SDTI 270 Mbps
|
|
Interface, ASI: Standard Frequency |
DVB-ASI, CENELEC EN 50083-9 270 Mbps
|
|
JPEG2000: Standard Capacity Ranges |
ISO/IEC 15444-1 Sum of compressed streams < 1000 Mbps SD-SDI: 10 – 50 Mbps (max 4 streams, 8 in future) HD-SDI: 10 – 250 Mbps (max 4 streams) 3G-SDI: 10 – 500 Mbps (max 2 streams)
|
|
Mapping: Transport |
DTM (Uncompressed), MXF/DTM (compressed)
|
|
Performance management: Bins Parameters |
ITU-T G.826 based 24h, 15min ES, SES, BBE, UAS |
|
Maintenance: Hardware Firmware |
Hot-swap Remote download
|
|
Environmental conditions: Operating temperature (short term) Storage temperature Relative humidity |
5 to 40 ºC (41 to 104 ºF) -5 to 55 ºC (23 to 131 ºF) -40 to 70ºC (-40 to 156 ºF) 10% to 90% (non-condensing)
|
|
Regulatory compliance: Safety EMC CE marking Evironment |
UL60950-1; EN60950-1 FCC 15 Class A; EN 300 386 93/68/EE RoHS directive 2002/95/EC
|
|
Management: Element Management Network Manegement |
Command Line Interface (CLI) and Web GUI Nimbra Vision™ or 3rd party NMS over SNMP v1/v2c/v3
|